Wednesday, 13 May 2015

NOx Monitoring in Gas Turbines



PROCESS:  

        A gas turbine is basically an engine.
First, the compressor compresses air and converts it to high pressure air.
Then, combustion takes place, and high pressure hot gas is produced.
In the last stage, energy is extracted from high pressure hot gases, and for instance a rotor is driven at high speeds.
 
        Control of combustion temperature plays an important role in running a gas turbine efficiently. If the combustion temperature increases, the NOx levels also increase, while the CO goes down. Reverse happens when the combustion temperature is brought down. A turbine therefore, has to be run at optimum temperature, to keep a control over NOx and CO levels.  Analysis Of Gas Turbine Systems
        A wear and tear of turbine parts is also indicated by an increase in NOx levels. Hence, it is very important to monitor exhaust gases coming out of a turbine.
 
MEASUREMENT:  O2, CO, and NOx are measured at the Gas Turbine exhaust.
SOLUTION: The testo340 with sensors for CO, NO, NO2 is the perfect solution.

Efficient measurement of Indoor Air Quality



The wide range of electronic instruments for the measurement of Indoor Air Quality available on the market reflects the many requirements in this area. Numerous parameters such as temperature, humidity, pressure or CO2 must be recorded, analyzed and documented. The professional groups carrying out measurements in the field of air conditioning and ventilation are equally varied: from contractors to plumbing, heating and air conditioning experts or plant constructors, up to expert appraisers or assessors. However, these users often apply only measuring instruments which are able to record one or two parameters belonging to their main activities. Yet especially those instruments which can measure almost all IAQ parameters support the efficient processing and management of the corresponding data. They would considerably facilitate work for all professional groups in air conditioning and ventilation technology.

The application

Which is the right instrument? A plumbing, heating and air conditioning expert uses an infrared temperature measurement to check insulation work on a heating system. Complex documentation is not necessary, so that as a rule, an entry instrument is sufficient. However, as soon as commissioning, installation, inspection or maintenance of ventilation and air conditioning systems (VAC) is necessary, more complex measurements are often required. For example, if there is a lack of well-being in open-plan offices, it becomes necessary to analyze draughts, uncomfortable temperatures or fatigue due to high CO2 concentrations. Such measurements can take several hours or days, and cannot be be managed with an entry instrument. It is recommended in such cases that professional measurement technology is used, which is able not only to measure many different parameters, but also to analyze and correspondingly document them for the customer.

The solution Pro measurement technology from Testo

Modern measuring instruments such as the VAC measuring instrument testo 480 have a high level of convenience for the user, as well as efficient analysis, processing and management of large quantities of data using PC software. They support the customer with integrated measurement programs which allow fast and standardized measurement. What makes them special is the large selection of digital probes which provide considerable advantages. On the one hand they appreciably extend the area of activity of the user. There is hardly an IAQ measurement which cannot be conducted. On the other hand, the probes produce a digital signal which is transferred to the measuring instrument completely without any loss of information, and free of error. The technical measurement intelligence is thus in the probe itself. This means it can be calibrated even without using a portable instrument, avoiding downtime costs and substantially simplifying the entire calibration process.

Benefits for the customer A win-win situation testo 480 with its probes fulfils numerous standards such as grid measurement of a VAC system according to EN 12599. The technician is prepared for everything, works quickly, obtains error-free measurement results and can present them to his customer directly on site. The customer can be certain that the technician conducts all relevant measurements and can adjust the VAC system according to the standards. And not only that, people have a greater sense of well-being, and it has been proven that they perform better at the workplace when the indoor climate is right. In addition to this, an efficiently adjusted system can avoid high energy costs. That saves the customer money.

COMBUSTION IN A BOILER FURNACE



PROCESS:  a mixture of fuel and air are burned inside the combustion zone, in a boiler or a furnace. It is not easy to properly mix the fuel and air, inside the chamber. So to ensure that every fuel molecule will find sufficient oxygen to combine with, and form carbon dioxide, an excess or extra of air is admitted along with the fuel.

This excess air has a simple objective, it has to make itself available for the fuel molecules, to combine. It does not take part in the reaction. After every single fuel molecule is burned, whatever excess air was given in the beginning, comes out thru the stack, along with the other flue gases.
The oxygen concentration in this air is measured, and it tells us whether the combustion is complete and has been efficient. Less than adequate oxygen, measured in the stack,  tells us that the fuel  doesn’t get sufficient oxygen, and so some of the fuel is left unburnt, and maybe CO is also produced. Combustion Analysis System.

More than adequate oxygen tells us that whatever heat is produced in the chamber, is taken away by the extra air that is given along with the fuel. This heat loss also means inefficient combustion in a way.

MEASUREMENT:  for this application , it is always O2, CO, and CO2 that are monitored. O2 tells us the type of combustion. The CO levels tell us how much fine tuning is required for the air to fuel ratio.

SOLUTION: for this application, for all small boilers, testo310, 320 and 330-LL can be offered. And for large power plants, and bigger boilers and furnaces, 340, and 350 are the right solutions. Ofcourse with O2 and CO sensor, and CO2 is always calculated.

Tuesday, 28 April 2015

EMISSION MONITORING IN BOILERS AND FURNACES



PROCESS:  In every combustion system, a fuel and air mixture is burned inside the combustion chamber. All liquid, solid, and gas fuels are basically hydrocarbons, and the process of burning results into production of various air pollutants. Especially uncontrolled combustion produces a high concentration of pollutants.  These pollutants damage the environment and are harmful to the population as well as the vegetation in the nearby areas where such plants are located.

It is very important that pollutants like CO, NO, NO2, SO2, HC, H2S, and to some extent, CO2, need to be monitored, so that they can be controlled later. Pollution Control Board has certain norms, and industries have to adhere to such norms and regulate the hazardous emissions, released from their exhausts.

MEASUREMENT:  In the combustion exhaust, gases like CO, NO, NO2, SO2, HC are to be measured in the stack, of all burning processes in boilers, furnaces, incinerators, and heaters.
SOLUTION: testo 340 and testo 350 with 4 and 6 sensors can be used in this application, depending on the no of gases to be measured by the client, and the other process conditions.

Into the digital age with analog measurement methods?



Digital technology is now found in all areas of life, often simplifying our daily routine. The refrigeration trade is no exception. And yet analog manifolds are still very widespread in refrigeration technology. This is a worrying development, because according to a number of studies, up to 74% of all refrigeration systems are incorrectly adjusted using the analog measurement method*. Not because of the qualification of the refrigeration technicians, but as a result of the insufficient accuracy and possibilities provided by analog manifolds.

The application
Measure more than just high and low pressure. The jobs involved in the construction of refrigeration systems are extremely diverse, reaching from project planning via installation and commissioning to maintenance and servicing of refrigeration and air conditioning systems or heat pumps. In order to ensure that a system is functional, the technician must always address the question of the respective pressures and temperatures of the refrigerant, and in particular the superheating and subcooling of the system. From these parameters, the operational status of the system can be determined, and information on its safety and efficiency obtained. The limits of what a technician can do are soon reached using an analog manifold for these wide-ranging activities, because these manifolds record only the high and low pressure of a refrigeration system. For every other measurement, for instance of temperature, an additional measuring instrument is needed. The complicated handling, the time needed for a measurement and the excessive room for interpretation in the recording of the measurement results do the rest. The consequences: inefficiently adjusted systems and additional costs for the customer.

The solution
The ideal multi-function instrument. Modern manifolds such as the testo 570 do justice to the daily requirements in the refrgieration trade. They record various operating parameters with only one instrument. This means that pressure as well as temperature values can be measured quickly and easily. Two temperature inputs as a rule also ensure the simultaneous calculation of the superheating and subcooling of the system. Many digital manifolds furthermore support the evacuation of the system with the help of an integrated vacuum measurement. It is also possible to conduct a temperature-compensated tightness test. In addition to this, almost all common refrigerants are stored in the instrument as standard. More modern instruments even allow data storage and analysis on a PC using special software, or the printout of the measurement protocol direct on site with the customer. The multi-functionality of digital manifolds thus creates considerable handling advantages, allowing fast and efficient work on site.

Benefits for the customer
In the age of energy efficiency. Against the background of the current discussion on the optimization of energy efficiency in technical systems, as well as the reduction of CO2 emissions, the accuracy of measurement results is of ever increasing significance. So it is time to replace the analog manifold with a digital one, because a manometer block can never provide a comprehensive picture of the status of a refrigeration system. However, the more precise the measurement results, the more reliably the working points, and thus the energy efficiency of a system can be determined. The possible potential for energy cost savings can be up to 12%*. The refrigeration technician saves time and costs not only for the customer, but also for himself. And as a bonus, he can be absolutely sure of the quality of his work.