Saturday, 23 December 2017

Testo 440 Air Velocity and IAQ Measuring Instrument is Available in Two Versions


The testo 440 dP form likewise has a coordinated differential weight sensor. This influences estimations at channels and also Pitot to tube and K-factor estimations conceivable.

With testo 440 estimation is conceivable in channels, at outlets, in rooms, at channels or with Pitot tubes

Estimations in channels

testo 440 Hot Wire Kit 

testo 440 air velocity and IAQ measuring instrument with inward memory and information trade work

Hot wire test incl. temperature sensor, settled link (1.8 m) with telescope (0.85 m)

Measurement menu, e.g. for deciding the volume stream and coordinated and multi-point mean estimation Basic case for testo 440 and 1 test

testo 440 

16 mm Vane Kit 

testo 440 air velocity and IAQ measuring instrument with inner memory and information send out capacity

Vane test, settled link (1.8 m) with telescope (0.85 m)

Measurement menu, e.g. for deciding the volume stream and coordinated and multi-point mean estimation Basic case for testo 440 and 1 test

Estimations at outlets 

testo 440 

100 mm Vane Kit with BT 

testo 440 air velocity and IAQ measuring instrument with inner memory and information trade work

100 mm vane test with Bluetooth, incl. temperature sensor

Measurement menu, e.g. for deciding the volume stream

Basic case for testo 440 and 1 test

The testo 440 test framework: 

In conduits, at outlets, in rooms, at channels or with Pitot tubes. 

All testo 440 air velocity tests for estimations in conduits have a scaled, extendible telescope (alternatively extendible from 1 m to 2 m).

With the testo 440 dP, incl. differential weight sensor, you can guarantee that the channels in ventilating frameworks are working legitimately.

The 100 mm vane test can be immediately joined with the 90° edge and telescope, making estimations at roof outlets less demanding.

If Bluetooth isn't conceivable: just switch test head over from Bluetooth to link deal with and you're prepared.

For volume stream estimations on account of high stream speeds or vigorously defiled stream, we prescribe the testo 440 dP and a Pitot tube.

Estimations in channels, at outlets and channel checking. 

testo 440 

Air flow ComboKit 1 with BT 

testo 440 air velocity and IAQ measuring instrument with inward memory and information send out capacity

100 mm vane test with Bluetooth, incl. temperature sensor

Hot wire test with telescope (0.85 m) incl. temperature sensor, settled link (1.8 m)

Measurement menu, e.g. for deciding the volume stream

Combi case for testo 440 and different tests

As ComboKit 2 with 100 mm and 16 mm vane test (arrange no. 0563 4407)

testo 440 delta P

Air flow ComboKit 1 with BT

o testo 440 dP air speed and IAQ measuring

o instrument incl. differential weight with interior

o memory and information send out capacity

o Universal test handle with Bluetooth

o Hot wire test head incl. temperature and mugginess sensor

o 100 mm vane test head incl. temperature sensor

o Telescope (1 m) and 90° plot for the two tests

o Combi case for testo 440 dP and numerous tests

testo 440 delta P 

Air flow ComboKit 2 with BT

testo 440 dP air velocity and IAQ measuring instrument incl. differential weight with inside memory and information trade work

Universal test handle with Bluetooth

16 mm vane test head

100 mm vane test head incl. temperature sensor

Humidity test head incl. temperature sensor

Telescope (1 m) and 90° plot for the two tests Combi case for testo 440 dP and numerous tests

Thursday, 18 August 2016

Automatic Monitoring & Documentation of Temperatures in Food Cold Chain with Testo Wi-Fi Data Logger

If it is about food, then it goes without saying that only hygienically immaculate goods are expected by the consumers. Undoubtedly, being the basic necessity of life good quality food stuffs is the highest priority for all consumers, food suppliers and manufactures. Be it vegetables, meat and sausages, poultry or dairy products- no one in the entire cold chain simply can afford bad quality because the customers would not accept damaged products.

Impediments to Safe & quality food throughout the supply chain
Right from farm to fork, there are many hindrances in supplying good quality food products - in Storage, transportation and other stages of supply chain. Firstly, the appearance of food items should be fresh and appetizing and not just that but the food also needs to be hygienically immaculate - More so with the perishable goods. For example, when the cold chain is interrupted and the foods are exposed to excessively high temperatures over a longer period. And secondly, because guidelines such as the HACCP concept must be strictly adhered to in order to eliminate risk factors.

This means that foods must be stored continuously at defined temperature limit values, typically at least -18 °C for deep-frozen goods and +4 °C to +8 °C in the refrigerated range. If refrigeration temperatures are not adhered to, leading to the sale of spoilt foods, there is a threat of considerable economic damage. All this often results due to failure or poor monitoring systems.
Conventional measurement data monitoring systems do automate monitoring. However, for this area of application they are often too complex, need time consuming installation, above all one person is always responsible for collecting the data and documenting them, by hand or electronically. Another setback surfaces due to the lack of warning and intimation features.

A Step ahead of Conventions
Considering the preferences of consumers, the indispensable norms that are to be followed and the quality level that has to be maintained, testo provides a superior alternative that can be easily induced in entire food monitoring system and supply chain, called as testo Saveris 2 - WiFi data loggers.

The Wi-Fi data logger system is the simple, flexible and reliable solution to humidity and temperature monitoring in food application for all workflow processes. The Wi-Fi data loggers measure temperature and humidity values via internal or external sensors and transmit the measurement data by wireless LAN to a server. With a secure online storage of all readings in Testo Cloud the data can be managed and analyzed online by the user via smartphone absolutely anywhere and anytime. The great advantage of testo Saveris 2 is its simplicity. This innovative monitoring system not only ensures easy installation & governing but eventually saves your time by almost eliminating manual readout and documentation procedures, simplifying the assurance of high product quality. In case of crises and deviations, it is even integrated with an alarm facility by e-mail, or optionally by SMS.
Test Saveris 2
Wi-Fi Data Loggers – Perfect solution for Food Industry
With the WiFi data logger system testo Saveris 2, you monitor and document the temperatures at all refrigerated sites automatically and more securely than ever before. You increase your operative efficiency, ensure quality, and prevent potential damage to the product and to your reputation - while adhering to laws, standards and regulations. It enables you to maintain constant, uniform and necessary conditions for your food products & gives necessary reminders and warnings as well.

To know more, or to see a live demo, write back to us on: info@testoindia.com Or Log on to our website www.testo.in https://www.testo.com/en-IN

Carry out Norm-compliant VAC Grid Measurement-with the Multi-function Measuring Instrument Testo 480

In order to be able to guarantee the error-free and energy-efficient performance of a VAC system, the correct adjustment of the total volume flow must be proven. In an incorrectly adjusted system, the indoor air quality deteriorates, which can negatively influence the health of the staff or production quality. This is why is important that in approval testing or when servicing a system, VAC technicians carry out a reliable, but also ve+ry complex VAC grid measurement according to EN 12599.

With the multi-function measuring instrument testo 480, Testo greatly simplifies VAC grid measurement – offering VAC constructors, assessors and facility managers a guided measurement program for norm-compliant results, as well as a large selection of highly accurate probes for the various requirements of the measurement.

Whether a VAC system fulfils the prescribed total volume flow, thus guaranteeing the required indoor climate, must be tested and proven according to the extensive guidelines of EN 12599 in approval testing and when servicing. As the flow profile in the duct rarely corresponds to the ideal shape (laminar/turbulent), and since the velocity profile can be extreme depending on the distance to the next source of interference, a grid measurement offers the safest method of correctly calculating volume flow. However, this form of measurement is very complex, and depending on the shape size of the duct, requires different measuring instruments and procedures – in rectangular ducts the trivial method, for example, and in round ducts the centroidal axis method. In addition to this, errors are more likely in grid measurement. There are various causes for this, ranging from influences at the measurement location up to errors in the conversion calculations of results.

With the multi-function measuring instrument testo 480, you conduct VAC grid measurements norm-compliantly according to EN 12599. With an integrated measurement program, the instrument guides you step by step through the entire measurement process, and offers a number of highly accurate probes such as thermal probes, vane probes or Pitot tubes – for low, medium or high flow velocities and different duct shapes. Thanks to the intelligent calibration concept, the probes notify the measuring instrument as soon the next calibration is due. Digital probes can even be calibrated without the hand instrument, allowing the uninterrupted use of the testo 480.

The measurement procedure is structured and simple:. First you enter the necessary parameters, such as duct geometry, distance from the edge or aperture position of the measurement location, into the menu. You then start the measurement program, whose graphic support guides you reliably and quickly through the measurement. The different measurement points in the duct are approached sequentially according to their coordinates. After the end of the measurement, the mean values as well as the uncertainties for flow velocity and volume flow are automatically calculated and displayed. This allows the total uncertainty to be directly evaluated without any additional measurements. With the testo 480, you are prepared for everything, you work quickly, obtain error-free measurement results, and can present them to your customers directly on site.

testo 480 – all the advantages at a glance:

Guided measurement program for norm-compliant measurements according to EN 12599

Compete probe range for the various requirements of VAC grid measurement

Intelligent calibration concept for maximum efficiency

More information.


For more information and answers to all your questions concerning VAC grid measurements with the testo 480 at www.testo.com/en-IN

Wednesday, 3 August 2016

FOOD MEASUREMENT TECHNOLOGY FROM TESTO

If it is about food, then it goes without saying that only hygienically immaculate goods are expected by the consumers. Undoubtedly, being the basic necessity of life good quality food stuffs is the highest priority for all consumers, food suppliers and manufactures. Be it vegetables, meat and sausages, poultry or dairy products- no one in the entire cold chain simply can afford bad quality because the customers would not accept damaged products.
Measurement of temperature is one vital aspect of food testing procedures and following the same, Testo brings to you a range of food temperature instruments.

Three reasons to use Testo food measurement technology
Highly precise: with Testo foodmeasuring instruments, you aresure to comply with limit values.
Hygienic and kitchen-safe: allfood thermometers, probes andloggers can be cleaned underrunning water, thus fulfilling IP65.
HACCP-certified quality: foreven more safety in the food flow

Food protectors from Testo
Penetration Thermometers: A whole range of penetration thermometers including Testo 103, Testo 104, Testo 105, Testo 106, Testo 108 and Testo 926 provide one with basic features that are necessary for temperature measurement in food stuffs. Each one of them is embedded with specific user friendly attributes. Some common features of the penetration thermometers are:
  • Washable
  • Pocket fitting – easy to carry
  • Alarms for limit values
  • HACCP compliant
                              Testo 105        Testo 108      Testo 926

IR Penetration Thermometers: These thermometers are equipped with the Infra-red facility of temperature and have the following features in common:
  • Measure surface and core temperatures
  • Laser measurement ability
  • HACCP compliant
 Testo 104-IR        Testo 826-IR

To know more, or to see a live demo, write back to us on: info@testoindia.com 
Or Log on to our website www.testo.com/en-IN.


TESTO’S MULTI FUNCTION VAC GRID MEASURING INSTRUMENT – TESTO 480

In order to be able to guarantee the error-free and energy efficient performance of a VAC system, the correct adjustment of the total volume flow must be proven. Indian incorrectly adjusted system, the indoor air quality deteriorates, which can negatively influence the health of the staff or production quality. This is why is important that in approval testing or when servicing a system, VAC technicians carry out a reliable, but also very complex VAC grid measurement according to EN 2599.Carry out norm-compliant VAC grid measurements – with the multi-function measuring instrument testo 480.With the multi-function measuring instrument testo 480,Testo greatly simplifies VAC grid measurement – offering VAC constructors, assessors and facility managers a guided measurement program for norm-compliant results, as well as a large selection of highly accurate probes for the various requirements of the measurement.

The challenge
Whether a VAC system fulfils the prescribed total volume flow, thus guaranteeing the required indoor climate, must be tested and proven according to the extensive guide lines of EN 12599 in approval testing and when servicing. As the flow profile in the duct rarely corresponds to the ideal shape (laminar/turbulent), and since the velocity profile can be extreme depending on the distance to the next source of interference, a grid measurement offers the safest method of correctly calculating volume flow. However, this form of measurement is very complex, and depending on the shape size of the duct, requires different measuring instrument sand procedures – in rectangular ducts the trivial method, for example, and in round ducts the centroidal axis method. In addition to this, errors are more likely in grid measurement.There are various causes for this, ranging from influences at the measurement location up to errors in the conversion calculations of results.

The solution
With the multi-function measuring instrument testo 480,you conduct VAC grid measurements norm-compliantly according to EN 12599. With an integrated measurement program, the instrument guides you step by step through the entire measurement process, and offers a number of highly accurate probes such as thermal probes, vane probesor Pitot tubes – for low, medium or high flow velocities and different duct shapes. Thanks to the intelligent calibration concept, the probes notify the measuring instrument as soon the next calibration is due. Digital probes can even be calibrated without the hand instrument, allowing the uninterrupted use of the testo 480.

The measurement procedure is structured and simple:
First you enter the necessary parameters, such as duct geometry, distance from the edge or aperture position of the measurement location, into the menu. You then start the measurement program, whose graphic support guides you reliably and quickly through the measurement. The different measurement points in the duct are approached sequentially according to their coordinates. After the end of the measurement, the mean values as well as the uncertainties for flow velocity and volume flow are automatically calculated and displayed. This allows the total uncertainty to be directly evaluated without any additional measurements. With the testo 480, you are prepared for everything, you work quickly, obtain error-free measurement results, and can present them to your customers directly onsite.

testo 480 – all the advantages at a glance
• Guided measurement program for norm-compliant measurements according to EN 12599
• Compete probe range for the various requirements of VAC grid measurement
• Intelligent calibration concept for maximum efficiency

                                   
                                                                  Testo 480 in use

For more information and answers to all your questions concerning VAC grid measurements with the testo 480 at www.testo.com/en-IN.

Tuesday, 28 June 2016

The NEW Cooking Oil Tester Testo 270- Because Every Drop is Valuable

Use of cooking oil which is too old for deep-frying produces inferior quality of food. It may also contain substances which present a risk to health. On the contrary, too early replacement of cooking oil causes wastage.

With the launch of new generation of the proven cooking oil tester testo 270 you can now inspect the quality of cooking oil for producing healthy food even faster. The cooking oil tester testo 270 measures the Total Polar Material (TPM) content in the cooking oil, which is a sure indicator of its quality with best potential of cooking oil between 14 and 20 % TPM. Regular measurement with the testo 270 prevents the use of oil which is too old along with preventing the wastage of cooking oil due to too early replacement thus ensuring the quality of deep-fried foods, and reducing expenditure for cooking oil by up to 20 % and therefore saving cost!

The new cooking oil tester has more robust connections between the housing, the probe shaft and the sensor along with considerably improved probe shaft strength over the previous model. In addition to this, the measuring instrument also fulfils the protection class IP65 even without an additional protective case which makes cleaning it under running water possible – ideal for use in quick-service restaurants. The ergonomic design of the new testo 270 offers an added advantage to the user by avoiding direct exposure to the heat from the deep-fryer while taking the measurement, allowing more safety.

The 86% larger display of the new testo 270 considerably simplifies the reading of temperature and TPM values along with the unmistakeable alarm provided by multi-colour backlighting which makes it even easier to evaluate the quality of the cooking oil; Green means that the TPM content is below the set limit value, orange is close to it, and when the display lights up red, the limit value has been exceeded. 

Monday, 20 June 2016

Ventilation and Air Conditioning Measurement Technology from Testo

VAC measuring instruments from Testo provide the highest level of precision from 0.01 m/s to 9999 m3/h. For any air conditioning and ventilation professional, measuring flow velocity accurately is not easy. Whether for the precise determination of volume flow, quick spot measurements in ducts or recording turbulent flows at outlets – without suitable measuring instruments, it is impossible to ensure optimum indoor air in residential and non-residential buildings

For this reason, Testo offers the optimum solution for every measurement task and measurement range: whether thermal probes, vane anemometers, differential pressure measuring instruments or multifunction instruments. Our patented flow straighteners provide added precision, even in turbulence at outlets. Find information now on how to measure flow velocity more efficiently.


Accurate measurement in ducts

You obtain the most accurate results when you measure directly in the duct. To compensate non-homogenous flows, a grid measurement is recommended. For this purpose, you determine the flow velocity values at several points in the duct cross-section, enter the cross-section dimensions – and your ventilationmeasuring instrument from Testo calculates the mean value and the volume flow for you automatically and reliably.

Precise measurement at outlets

If the ventilation duct is inaccessible, the measurement takes place directly at the outlet. In adjustment work too, the air input and output is tested where the air flows into the room. However, turbulent flows at swirl and plate outlets can severely falsify your measurement results. For this reason, we recommend the use of funnel measuring instruments with a flow straightener (testo 420, testo 417 set 2).

Multifunctional measurement in ducts and at outlets

Multifunction measuring instruments give you as a VAC professional maximum flexibility. The multifunction VAC measuring instruments testo 435-4 and testo 480 can be extended with various probes. In addition to flow velocity, volume flow, temperature and humidity, you measure absolute and differential pressure, light intensity, radiated heat, degree of turbulence and CO2 concentration – with only one instrument.

Testo India Pvt. Ltd., a 100% subsidiary of Testo AG, Germany was founded in 2006 in Pune. The company has established thirteen home offices in major metros and a dealers’ network covering this enormous country.

Testo AG is a world leader in the design, development and manufacturing of portable test and measuring instruments. Testo has also become a major supplier for HVAC industries, refrigeration, airflow and environmental monitoring instruments for markets as diverse as chemical, steel, power, cement, food and beverages, pharmaceuticals, biotech etc. Today, Testo consists of 2500 employees, 31 subsidiaries and 80 sales & service partners in other 43 countries.